Bugs found in Software Ideas Modeler please report here.
23 September 2009 23:19:38
Rajesh Roy
10 December 2010 2:07:57
Lost alignment of components in Sequence Diagram
Hi
I am using current verson 4.81. After saving my project, existing the tool and reopening a saved project, I am loosing all alignment of components in sequence diagram. Each time realigning whenever I open a project is painful. Can you please reasolve this ?
Dusan Rodina - softwareideas.net
10 December 2010 11:05:23
RE: Lost alignment of components in Sequence Diagr
Hi,
I cannot reproduce this issue. Could you send me, please, some example screenshots which show the diagram before exiting the application and after reopening to my e-mail.
RE: RE: Lost alignment of components in Sequence D
Hi
I have sent you an email. I have more than one sequence diagrams in a single project. By opening, saving and closing project multiple times will start moving all action call and return call lines and messages go in upward direction of the diagram.
'Extension points' not removed after deletion of e
In Use case diagram, if I add an extension the Use case gets an artifact station 'Extension points'. However if I delete the extension, the Use case is not restored ('Extension points' artifact removed).
I don't know how it is supposed to work, but I created a package in one diagram an then I copied this instance to another diagram by selecting it in the hierarcial view.
There is some kind of icon displayed above the package (like a blue little camera or something) and I guess that symbol illustrates that the instance is reused.
I added some object to the package in one diagram (Use Case) but the second instance did not change, showing the new content. However, if I changed the name, that change was displayed in both instances.
My guess is that there should be only one single entity that is shared between the diagrams and that an edit in one place should show in the other? Or have I misunderstood the purpose?
I'm working on a Use case diagram and decided to move some use cases into a System boundary object, and these use cases was already connected to both other use cases and actors that stayed outside the system boundary.
I found that many connectors (Associations and Generalizations) was not selectable until I manually selected them using the hierarcial view in the right pane and applied Arrange -> Order -> Bring to front.
The connectors where visible on screen, but was rendered as behind the system boundary box in print preview.
I would like to see that the connectors 'follows' the object connected to when doing these kinds of wrapping changes.
I was trying to align some shapes. With 'snap to grid' enabled. Some shapes don't align nicely, because they are different sizes. So when I resize the shapes the connection like an arrow forms a horizontal or vertical line. If I don't resize, the connection is a little off horizontal or vertical. A little annoying and it takes work to resize all shapes.
Rajesh Roy 10 December 2010 2:07:57
Lost alignment of components in Sequence Diagram
Dusan Rodina - softwareideas.net 10 December 2010 11:05:23
RE: Lost alignment of components in Sequence Diagr
Rajesh Roy 11 December 2010 1:37:12
RE: RE: Lost alignment of components in Sequence D
Dusan Rodina - softwareideas.net 14 December 2010 23:40:35
RE: RE: RE: Lost alignment of components in Sequen
Tomas Sandkvist 9 December 2010 15:56:13
Use case diagram lacks realization arrow
Dusan Rodina - softwareideas.net 14 December 2010 23:41:10
RE: Use case diagram lacks realization arrow
Tomas Sandkvist 9 December 2010 15:53:13
'Extension points' not removed after deletion of e
Dusan Rodina - softwareideas.net 14 December 2010 23:41:34
RE: 'Extension points' not removed after deletion
Tomas Sandkvist 9 December 2010 13:12:07
Arrow keys
Dusan Rodina - softwareideas.net 14 December 2010 23:41:54
RE: Arrow keys
Tomas Sandkvist 9 December 2010 12:56:24
A reused instance does not update if edited
Dusan Rodina - softwareideas.net 10 December 2010 11:29:47
RE: A reused instance does not update if edited
Tomas Sandkvist 9 December 2010 8:15:55
System boundary issues with connectors
Dusan Rodina - softwareideas.net 9 December 2010 10:13:47
RE: System boundary issues with connectors
Tomas Sandkvist 9 December 2010 8:10:39
Print dialog 'locks' to default printer
Dusan Rodina - softwareideas.net 14 December 2010 23:42:52
RE: Print dialog 'locks' to default printer
Jeroen Meijer 8 December 2010 20:02:44
Dusan Rodina - softwareideas.net 14 December 2010 23:54:23
RE:
Saša Ćetković 8 December 2010 14:37:59
Error during XMI import
Dusan Rodina - softwareideas.net 14 December 2010 23:47:42
RE: Error during XMI import